Electrolytic Copper Conductor Conforming To IS : 8130

Highly Abrasion Resistant.
Long Working Life.
Less Heat Build UP.
Ozone Resistant.
Unconditional Guarantee for 12 monts
   
comparative chart of TRS & HOFR / export Quality HOFR
"sterco" copper conductor welding cables
Conductor
Area in Sq. MM
No.of wires / sizes current     carrying     capacity
at 60% duty cycle conforming to is : 9857 / 90
    General Purpose TRS Welding Cable ( AMPS. ) HOFR / EXPORT
Quality HOFR Welding
Cable ( AMPS. )
16 509 / 0.2 121 174
25 796 / 0.2 161 228
35 1114 / 0.2 201 285
50 708 / 0.3 254 360
70 999 / 0.3 320 454
95 1351 / 0.3 386 547
"STERCO" ALUMINIUM CONDUCTOR WELDING CABLES
25 355 / 0.3 129 186
35 494 / 0.3 159 227
50 708 / 0.3 200 287
70 999 / 0.3 253 361
95 1351 / 0.3 306 438
120 1691 / 0.3 365 522
 
SAVE MONEY BY EFFECTIVE USE OF HOFR / EXPORT QUALITY HOFR OVER GENERAL PURPOSE TRS WELDING CABLE.

EXAMPLE : SUPPOSE SOME BODY IS USING 25 Sq. MM TRS WELDING CABLE RATED FOR 161 AMPS. ALTERNATIVELY HE CAN USE 16 Sq. MM HOFR / EXPORT QUALITY HOFR WELDING CABLE RATED FOR 174 AMPS.
HOFR - BLACK COLOUR EXPORT QUALITY HOFR-ORANGE COLOUR

   
  Ambient Temperature 300 C
  Max. Conductor Temperature : TRS - 600 C , HOFR / EXPORT QUALITY HOFR - 900 C.

 

 